SCF Reference Manual for the Storage Subsystem (G06.28+, H06.05+, J06.03+)
Recovery
1. Take online dump for the affected DP2 processors. After the online dump is completed, use
SCF START DISK command to restart the affected DP2 processes, which resets the state of
the processes. Online dump action must be completed before starting the disk process.
2. If the problem persists, contact your service provider. See “Upgrade and Replacement
Procedures” (page 362) for additional information.
01001
STORAGE 01001 Must perform disk revive: volname
volname
is the name of the volume that you specified in the command.
Cause
One of the disks of a mirrored volume is not current with the other disk. A disk revive operation
is required.
Effect
The disk revive operation is started.
Recovery
Informational message only; no corrective action is required. SCF initializes a disk revive
operation.
01002
STORAGE 01002 objtype devname is state. Please use RESET command.
objtype
is the object type of the object you specified with the command.
devname
is the name of the device you specified in the command.
state
is the current state of the device you specified in the command.
Cause
The device is in a state from which it cannot be started.
Effect
The device is not started.
Recovery
Issue an SCF RESET command.
01003
STORAGE 01003 command rejected, a disk revive is in progress.
command
is the SCF command that you issued.
Cause
The operation cannot be performed because a disk revive operation is still in progress.
Effect
The command is not executed.
Recovery
Verify the state of the device by using the SCF STATUS command. Either wait until the revive
operation is completed or if you need to temporarily stop the revive operation, use the SCF
RESET command to suspend the revive operation before retrying the operation.
334 Storage Subsystem Error Messages