SCF Reference Manual for the Storage Subsystem (G06.28+, H06.05+, J06.03+)
Recovery
Either:
• Reissue the SCF command interactively.
• Remove the command from the SCF command file.
01051
STORAGE 01051 The label is bad on disk device devname. The label was not altered.
devname
is the name of the device you specified in the command.
Cause
The label is bad on the indicated disk. Either the time stamp or the last mounted operating system
(OS) field is null.
Effect
The command is not executed.
Recovery
Either:
• Revive the disk volume using the SCF START DISK command.
• Use the SCF INITIALIZE DISK or ALTER DISK, LABEL command to write a new label onto the
disk, if required. Writing a new label deletes any existing files on the disk.
01053
STORAGE 01053 The REPLACE DISK volname command is not supported in non-interactive mode.
volname
is the name of the volume that you specified in the command.
Cause
You have not used the REPLACE command from interactive mode.
Effect
The command is not executed.
Recovery
Reissue the REPLACE command from an interactive prompt.
01054
STORAGE 01054 command devname failed. Impossible, 3-cable configuration
implied by other devices using the same SAC.
command
is the SCF command that you issued.
devname
is the name of the device you specified in the command.
Cause
You attempted to add a device that requires a cable configuration that is not possible, given the
other devices using the same ServerNet addressable controller (SAC).
Effect
The command is not executed.
Recovery
Reissue the command, specifying a different value for the SAC or the corresponding backup
SAC.
01055
STORAGE 01055 command devname failed. Attribute cannot be decreased while devname is in a STARTED state.