SCF Reference Manual for the Storage Subsystem (G06.28+, H06.05+, J06.03+)
Effect
The command is executed. The checksum is corrected. This is a warning.
Recovery
Find the data on the sector using INFO DISK, SECTOR and then verify that it is valid.
01063
STORAGE E01063 Command failed. Another disk using the same adapter shares one CPU but not both CPUs.
Cause
Another disk using the same adapter shares one CPU but not both CPUs. This configuration is
not supported on G-series RVUs prior to G06.27 or on the H06.03 RVU.
Effect
The command is not executed.
Recovery
Use INFO ADAPTER, DETAIL to see other disks using the same adapter. Then reissue the
command, specifying different values for the LOCATIONs or the CPUs.
01064
STORAGE E01064 Command failed. Another disk using the same adapter shares a CPU but not both adapters.
Cause
Another disk using the same adapter shares a CPU but not both adapters. This configuration is
not supported on G-series RVUs prior to G06.27 or on the H06.03 RVU.
Effect
The command is not executed.
Recovery
Use INFO ADAPTER, DETAIL to see other disks using the same adapter. Then reissue the
command, specifying different values for the LOCATIONs or the CPUs.
01065
STORAGE W01065 One or more of the specified attributes can not be immediately changed online.
Cause
One or more of the specified attributes can not be immediately changed to the specified value
while the volume is up. For example, some attributes can be increased online but not decreased.
Effect
Any specified attributes which can be changed immediately are successfully changed immediately.
All specified attributes are saved in the CONFIG file and will take effect at the next re-start of
the volume.
After this warning has occurred for a volume, additional changes to other online alterable
attributes will receive the same warning, until the deferred change takes effect.
Recovery
This is a warning. No action is necessary. Use STATUS DISK, CONFIG to view the values which
the running disk process is currently using. To force deferred changes to take effect, stop and
re-start the volume.
01066
STORAGE W01066 When a volume has WRITECACHE enabled, delta revive will not be allowed,
and the SUBSYS attribute UPS should be ON.
Cause
You enabled WRITECACHE for a volume.
Effect
Write caching will be enabled. Delta revive will not be allowed. Only full revive will be allowed
on the volume.
Storage Subsystem Error Messages 351