SCF Reference Manual for the Storage Subsystem (G06.28+, H06.05+, J06.03+)
Recovery
This is a warning. No action is required, but HP recommends that the volume be connected to
an HP rack mount UPS, which will give the drives enough time to write cached data to the media
after the processor stops writing in the event of power loss.
The SUBSYS attribute UPS should be ON either before WRITECACHE is enabled or before the
IOP is started. Otherwise, the IOP will run with WRITECACHE disabled.
01067
STORAGE W01067 Enabling FASTBULKWRITE can impact data integrity on a volume.
Cause
You set FASTBULKWRITE ON for a volume.
Effect
FASTBULKWRITE is turned ON. When ON, applications and utilities using bulk writes to
unstructured files may have higher throughput. Using FASTBULKWRITE ON can result in lost
data in unstructured files if the CPU running the primary disk process fails. This attribute only
affects disks in a disk drive enclosure or ESS disks.
Recovery
This is a warning. No action is required.
05001 Through 05999 SMF Messages
All messages with error numbers in the range 05001 through 05999 are generated by the Storage
Management Foundation (SMF). These messages are documented in the Storage Management
Foundation User’s Guide.
09001 Through 09036
09001
STORAGE 09001 cmd rejected, SMF MON is down. File system error: errnum
cmd
is the command that you issued.
errnum
is the error number provided by the file system.
Cause
The command you issued requires the master process to be running.
Effect
The command is not executed.
Recovery
Check the returned file-system error to determine what to do next.
09002
STORAGE 09002 cmd rejected, no definition with SMF MON. File system error: errnum
cmd
is the command that you issued.
errnum
is the error number provided by the file system.
Cause
There is no SMF MON definition for the device.
Effect
The command is not executed.
352 Storage Subsystem Error Messages