SCF Reference Manual for the Storage Subsystem (G06.28+, H06.05+, J06.03+)

Effect
The command is not executed.
Recovery
Delete the disks associated with the storage pool, then delete the storage pool. Use the SCF
INFO POOL, DETAIL command to see which disks are associated with a storage pool.
09029
STORAGE 09029 The attribute refers to a device of an incorrect type.
Cause
You specified an attribute that is incompatible with the type of device specified in the command.
Effect
The command is not executed.
Recovery
Change the command so that the device and attribute match. For example, if POOL is specified,
the name must be the name of a storage pool. If you specify the LIKE attribute, both object names
must be of the same type.
09030
STORAGE 09030 This disk is already associated with another pool.
Cause
You issued a command to associate a physical volume with a storage pool, but the volume is
already associated with another storage pool.
Effect
The command is not executed.
Recovery
Use the SCF ALTER command to delete the physical volume from the storage pool it is associated
with before attempting to associate it with a different storage pool.
09031
STORAGE 09031 This disk is not of the same sub type as specified.
Cause
The specified disk type does not support the specified attribute.
Effect
The command is not executed.
Recovery
Correct the command using the proper attribute for the disk type.
09032
STORAGE 09032 devname is not a disk in pool poolname.
devname
is the name of the device you specified in the command.
poolname
is the name of the storage pool you specified in the command.
Cause
You specified an incorrect name for either the disk or the storage pool.
Effect
The command is not executed.
Storage Subsystem Error Messages 359