Security Management Guide (G06.29+, H06.08+, J06.03+)
HP NonStop Port Details
Security Management Guide — 522283-021
E - 16
CLIM TCP/IP Ports
Table E-8, lists inbound CLIM ports on the customer LAN(s).
SNMP 161 No N/A snmp UDP
Racoon 500 No N/A IPSec Running whether or not
IPSec is con
figured on
the CLIM. This service
only runs on the
maintenance LAN for
CLIMs that do not
support multiple data
providers.
CLIM HP
sof
tware:
confsync,
cipssrv,
climagt
7777-
7780
No N/A UDP UDP; IPC within or
between CLIMs
Table E-8. Inbound CLIM Ports Open on the Customer LAN
Function Port
Reconfi
gurable
Reconfigur
a
ble Range Protocol Considerations
Racoon 500 No N/A IPSec
Running whether or not
IPSec is configured on
the CLIM.
Table E-7. Inbound CLIM Ports Open on the Maintenance LAN
Function Port
Reconfi
gurable
Reconfigur
able Range Protocol Considerations