ServerNet Cluster 6780 Operations Guide (G06.24+, H06.03+)
SCF Commands for the External ServerNet SAN
Manager Subsystem
ServerNet Cluster 6780 Operations Guide—525606-002
5-36
STATUS SWITCH Command Example
Config Image B
indicates the condition of the configuration stored in Image B of the switch. Two
images are stored for fault tolerance. Possible values are ok, CRC ERROR, and
UNKNOWN.
Logic Board Temp
indicates the temperature (in degrees centigrade) of the switch logic board.
Power (nn)
indicates the status for the switch power supply in slot nn. Possible values are:
•
ok
•
POWER SUPPLY ABSENT
•
AC OR POWER SUPPLY FAILED
•
MARGINAL POWER SUPPLY.
A value of MARGINAL POWER SUPPLY indicates that the power supply cannot
ride through 1/2 cycle dropouts and should be replaced.
Fan (nn)
indicates the condition of the switch fan in slot.nn. Switch fans are located in slots
16 and 17. Possible values are ok, FAILED, or UNKNOWN.
DC 3.0 (14)
indicates the state of the 3.0 volt DC power source on the switch logic board (CRU
14). Possible values are ok, FAILED, or UNKNOWN.
DC 2.5 (14)
indicates the state of the 2.5 volt DC power source on the switch logic board (CRU
14). Possible values are ok, FAILED, or UNKNOWN.
Router Status
lists the status for each of the 12 router ports (00 through 11) on the 5 routers (Rtr1
through Rtr5). For possible values, see Table 5-4, Router Status Codes.
CRU Slot (nn)
lists these details for the switch CRU in slot nn:
CRU Type
is the type of switch CRU in slot nn. For more information, see Table 5-3,
CRU Slots for the 6780 Switch.
If there is no CRU installed in the slot, ABSENT appears.
If the wrong CRU is installed in the slot, WRONG TYPE appears.