ServerNet Cluster 6780 Operations Guide (G06.24+, H06.03+)
SCF Commands for the External ServerNet SAN
Manager Subsystem
ServerNet Cluster 6780 Operations Guide—525606-002
5-37
STATUS SWITCH Command Example
State
is the state of the switch CRU in slot nn. Possible values are:
F-LED
is the state of the fault LED on the switch CRU in slot nn. Possible values are
BL (blinking), ON, and off.
If there are transceiver problems, SEE CRU STAT appears across the State and F-
LED columns. Use the CRU option of the STATUS SWITCH command to get more
information.
DS Disabled
ER Error
en Enabled
Table 5-4. Router Status Codes
CABS CRU absent
ICTG Invalid configuration tag
ICVI Invalid configuration version ID
INBR Invalid neighbor
ISCR Invalid switch configuration revision
LADS Link alive, disabled
LOS Lost optical signal
MPNK Manage port command naked
MPNR No response to manage port command
NCIP Neighbor check in progress
NOLA No link alive
RSET Reset
TABS Transceiver absent
UNGD Unmatched GUID
UNKN Unknown
UNSP Unmatched slot, port number, or both
WNBR Neighbor Check OK. Waiting on neighbor
en enabled