ServerNet Cluster 6780 Operations Guide (G06.24+, H06.03+)

SCF Error Messages
ServerNet Cluster 6780 Operations Guide525606-002
6-2
SCF Error Message Help
Like common errors, subsystem-specific error messages are divided into two
classes—critical and noncritical:
Critical messages can be serious, such as the notification of software errors for
which there is no automatic recovery. Critical messages are preceded by an E.
Noncritical messages are generally informational. Noncritical messages are
preceded by a W.
SCF Error Message Help
To request help for any SCF error message, type:
-> HELP subsystem error-number
For example, if these messages appear on your terminal:
SCL E00003 Internal error. Case value out of range.
SMN E00006 Processor switch failed.
SCF E20211 Invalid object type
To display additional information:
-> HELP SCL 3
-> HELP SMN 6
-> HELP SCF 20211
ServerNet Cluster (SCL) Error Messages
The ServerNet cluster subsystem SCF error messages are listed in numeric order.
SCL Error 00001
num
is the result code.
sysproc
is the name of the system procedure.
Cause. An internal error was caused by an unexpected return code from a system
procedure.
Effect. The command is not executed. SCF waits for the next command.
Recovery. Contact your service provider and retain a copy of the SCF, SCP,
OSIMAGE, and CONFLIST files. (See If You Have to Call Your Service Provider on
page 6-19.)
SCL E00001 Internal error: Result code num returned from
sysproc.