ServerNet Cluster 6780 Operations Guide (G06.24+, H06.03+)
SCF Error Messages
ServerNet Cluster 6780 Operations Guide—525606-002
6-16
SANMAN (SMN) Error Messages
SMN Error 00051
Cause. The command specified FAULTLEDS, but the specified switch does not
support the FAULTLEDS option.
Effect. The command is not executed. SCF waits for the next command.
Recovery. Correct and reissue the command.
SMN Error 00070
Cause. The LOCATOR string specified exceeds the 6770 switch limit of 32
characters.
Effect. The command is not executed. SCF waits for the next command.
Recovery. Correct and reissue the command.
SMN Error 00071
Cause. The command incorrectly specified a switch. Specify a model 6770 switch
using either the NEAREST or FABRIC specifier.
Effect. The command is not executed. SCF waits for the next command.
Recovery. Correct and reissue the command.
SMN Error 00072
Cause. The command incorrectly specified a switch. Specify a model 6770 switch
using either the FABRIC or ONLY specifier.
Effect. The command is not executed. SCF waits for the next command.
Recovery. Correct and reissue the command.
SMN E0051 FAULTLEDS attribute is not allowed for the
specified switch
SMN E00070 LOCATOR string longer that 32 characters.
SMN E00071 Incorrect specification of model 6770 switch.
SMN E00072 Incorrect specification of model 6770 switch.