SCF Error Messages
ServerNet Cluster 6780 Operations Guide—525606-002
6-17
SANMAN (SMN) Error Messages
SMN Error 00073
Cause. No POSITION was specified when loading a 6770 switch CONFIG file.
Effect. The command is not executed. SCF waits for the next command.
Recovery. Correct and reissue the command.
SMN Error 00074
Cause. POSITION 3 and TOPOLOGY 16NODES were specified in the command.
Effect. The command is not executed. SCF waits for the next command.
Recovery. Correct and reissue the command.
SMN Error 00075
Cause. The command specified a router-instance value. To display ROUTER
status from a 6770 switch, omit the router-instance value.
Effect. The command is not executed. SCF waits for the next command.
Recovery. Correct and reissue the command.
SMN Error 00076
Cause. No TOPOLOGY was specified when loading a 6770 switch CONFIG file.
Effect. The command is not executed. SCF waits for the next command.
Recovery. Correct and reissue the command.
SMN E00073 When loading a 6770 switch CONFIG file, POSITION
is required.
SMN E00074 POSITION 3 is only valid with TOPOLOGY 24NODES.
SMN E00075 ROUTER router-instance is not allowed for model
6770 switches.
SMN E00076 When loading a 6770 switch CONFIG file, TOPOLOGY
is required.