Checking the External ServerNet X and Y Fabrics
Checking the External ServerNet X and Y Fabrics
You use the OSM Service Connection to check the external ServerNet X and Y fabrics.
You can also perform internal and external loopback tests on an NNA PIC in an MSEB.
If no alarms are visible on the external fabrics, but you still want to check the
connectivity between the local node and the cluster switch, you can use the Node
Connectivity ServerNet Path Test action. This action tests a path from the local MSEB
to the 6780 switch module on one fabric. If problems are found, OSM generates alarms
based on the result. This action is provided for diagnostic purposes only. It has no
destructive effect.
Table 3-4 describes the scope of the Node Connectivity ServerNet Path Test action.
If an alarm is generated, the problem lies between the local node and the cluster
switch. The problem might be any of these components:
•
The MSEB in slot 51 or 52 of the group 01 enclosure of the local system
•
The PIC in port 6 of the MSEB in slot 51 or 52 of the group 01 enclosure of the
local system
•
The cable from the PIC in port 6 of the MSEB in slot 51 or 52 of the group 01
enclosure to a switch-to-node port of the 6780 switch module
•
The switch-to-node port to which the local system is connected
•
The PIC in slots 6 through 9 of the 6780 switch module that contains the switch-to-
node port to which the local system is connected
•
The 6780 switch module itself
To check ServerNet connectivity on the external fabrics:
1. Log on to the OSM Service Connection.
2. In the tree pane, expand the ServerNet Cluster resource.
Table 3-3. Scope of Node Connectivity ServerNet Path Test
On This
Fabric The test checks from . . . To the . . .
X fabric Port 6 of the MSEB in slot 51 of group 01 Switch-to-Node port of the X-
fabric 6780 switch module.
Y fabric Port 6 of the MSEB in slot 52 of group 01 Switch-to-Node port of the Y-
fabric 6780 switch module.
Note. An error is returned if you try to run this path test when another Node Connectivity
ServerNet Path Test is in progress on the same fabric. The Path Test in Progress attribute
indicates if a path test is currently being conducted on the fabric.