ServerNet Cluster 6780 Operations Guide (G06.28+, H06.05+)

SCF Commands for the External ServerNet SAN
Manager Subsystem
ServerNet Cluster 6780 Operations Guide525606-003
5-10
INFO CONNECTION Command
INFO CONNECTION Command
The INFO CONNECTION command obtains information about the external ServerNet
fabric connection to the nearest cluster switch. Unless specified otherwise, information
appears for both fabrics. This information is returned by the external ServerNet SAN
manager process ($ZZSMN). INFO is a nonsensitive command.
The INFO command syntax is:
OUT file-spec
causes any SCF output generated for this command to be directed to the specified
file.
FABRIC { X | Y } | ONLY { X | Y }
causes information for only the specified fabric (X or Y) to appear. ONLY and
FABRIC are synonymous in this case, and either can be used.
INFO CONNECTION Command Example
This example shows the INFO CONNECTION $ZZSMN command:
> INFO CONN $ZZSMN
INFO CONNECTION X Fabric Y Fabric
|----------------------------------------------------------------------------|
| Response Status | ok | ok |
| Rsp Status Detail | No Status Detail | No Status Detail |
|--------------------|---------------------------|---------------------------|
| Switch Type | Model 6780 | Model 6780 |
|--------------------|---------------------------|---------------------------|
| MSEB | Port Configuration | Port Configuration |
|--------------------|---------------------------|---------------------------|
| Port | 6 | 6 |
| PIC Type | NNA | NNA |
| NNA Version | 22 | 22 |
| Node Number Mask | 0x000ff000 | 0x000ff000 |
| Node Routing ID | 0x00094000 | 0x00094000 |
| SvNet Node Number | 19 | 19 |
|--------------------|---------------------------|---------------------------|
| ServerNet Switch | Port Configuration | Port Configuration |
|--------------------|---------------------------|---------------------------|
| CRU Slot | 7 | 7 |
| CRU Port | 1 | 1 |
| PIC Type | Dual SMF | Dual SMF |
| Transceiver | 9/125u SMF | 9/125u SMF |
| Desired Port State | n/a | n/a |
| Neighbor ID Check | Query No Resp Expected | Query No Resp Expected |
| Node Number Mask | 0x000ff000 | 0x000ff000 |
| Node Routing ID | 0x00094000 | 0x00094000 |
| SvNet Node Number | 19 | 19 |
|--------------------|---------------------------|---------------------------|
INFO [ / OUT file-spec / ] CONN[ECTION ] $ZZSMN
[ , FABRIC { X | Y } | , ONLY { X | Y } ]