ServerNet Cluster 6780 Operations Guide (G06.28+, H06.05+)

SCF Commands for the External ServerNet SAN
Manager Subsystem
ServerNet Cluster 6780 Operations Guide525606-003
5-15
INFO SWITCH Command
INFO SWITCH Command
The INFO SWITCH command obtains information about a specific cluster switch.
Unless specified otherwise, information is displayed for the X and Y switches. This
information is returned by the external ServerNet SAN manager process ($ZZSMN).
INFO is a nonsensitive command.
The INFO command syntax is:
OUT file-spec
causes any SCF output generated for this command to be directed to the specified
file.
FABRIC { X | Y } | ONLY { X | Y }
specifies that information for only the local switch on the specified fabric (X or Y)
be displayed. ONLY and FABRIC are synonymous in this case, and either can
be used. The local switch is the one directly connected to the node where you
issue this command.
[ FABRIC { X | Y } , ] ZONE znum , LAYER lnum
a string of identifiers that specifies the switch in a layered topology for which you
want information. The layered topology uses only 6780 switches.
FABRIC { X | Y }
specifies the external ServerNet fabric.
ZONE znum
specifies the cluster switch zone. znum must be in the range 1 through 3.
LAYER lnum
specifies the cluster switch layer. lnum must be in the range 1 through 4.
CRU cnum
specifies the CRU in a particular slot within a specified 6780 switch. If this optional
parameter is specified, only information for the CRU in the specified slot is
displayed. cnum must be in the range 1 through 18. Table 5-3 lists the types of
CRUs in the slots of a 6780 switch.
INFO [ / OUT file-spec / ] SWITCH $ZZSMN
[ , FABRIC { X | Y } | , ONLY { X | Y } ]
[ [ , FABRIC { X | Y } ] , ZONE znum , LAYER lnum ]
[ , ZONE znum , LAYER lnum ]
[ , [ CRU cnum ]