ServerNet Cluster 6780 Operations Guide (G06.28+, H06.05+)

SCF Commands for the External ServerNet SAN
Manager Subsystem
ServerNet Cluster 6780 Operations Guide525606-003
5-19
INFO SWITCH Command Example
Load Num Selector
represents a supported configuration image that is loaded in the 6780 switch
based on the numeric selector setting when the switch was reset. Each switch in a
layered topology has a unique 4-digit numeric selector setting. For a list of
possible numeric selector settings, see Table 3-5 on page 3-29.
Prev Num Selector
is the previous value of the numeric selector.
Curr Num Selector
is the current value of the numeric selector. If this value is not the same as the
Load Num Selector, it will be used the next time the switch is hard reset.
Globally Unique ID
is a unique character string used to identify the cluster switch. The GUID is stored
in nonvolatile memory (SEEPROM) on the cluster switch at the time of
manufacture. The GUID is not visible on the exterior of the switch.
Firmware Revision
is the version of firmware running on the cluster switch.
Firmware VPROC
is the VPROC string for the version of firmware running on the cluster switch. The
VPROC string is truncated in this display. To see the full VPROC string, use the
OSM Service Connection.
Image A VPROC (firmware)
is the VPROC string for the version of firmware stored in image A on the cluster
switch.
Image B VPROC (firmware)
is the VPROC string for the version of firmware stored in image B on the cluster
switch.
FPGA Version ID
is the version of the field programmable gate array (FPGA) running on the cluster
switch.
FPGA VPROC
is the VPROC string for the version of the FPGA running on the cluster switch. The
VPROC string is truncated in this display. To see the full VPROC string, use the
OSM Service Connection.