ServerNet Cluster 6780 Operations Guide (G06.28+, H06.05+)
SCF Commands for the External ServerNet SAN
Manager Subsystem
ServerNet Cluster 6780 Operations Guide—525606-003
5-23
LOAD SWITCH Command Examples
check the value of the Hardware Data ID attribute. If the value is MISMATCH,
perform a hard reset. If the value is match, perform a soft reset.
•
Wild cards are not supported for the LOAD SWITCH command.
•
You must perform a hard reset of the 6780 switch after an FPGA download.
LOAD SWITCH Command Examples
This example downloads the firmware file $SYSTEM.SYS05.M2789 to the 6780 switch
on the external ServerNet Y fabric in zone 3, layer 2:
> LOAD SWITCH $ZZSMN, FABRIC Y, ZONE 3, LAYER 2, FIRMWARE $SYSTEM.SYS05.M2789
This command should only be issued by Hewlett-Packard trained support
personnel. Executing this command will load a new firmware image on the
switch. Before executing this command, be sure to read the instructions for
switch firmware download in the NonStop S-series Service Provider Supplement.
Do you wish to continue with this command (Y/[N])?y
If the command is successful, SCF displays:
The switch has received the firmware file which will be put into use after
the next SOFT RESET command.
This example downloads the configuration file $SYSTEM.SYS05.C2790 to the 6780
switch on the external ServerNet Y fabric in zone 3, layer 2:
> LOAD SWITCH $ZZSMN, FABRIC Y, ZONE 3, LAYER 2, CONFIG $SYSTEM.SYS05.C2790
This command should only be issued by Hewlett-Packard trained support
personnel. Executing this command will load a new configuration image on the
switch. Before executing this command, be sure to read the instructions for
switch configuration download in the NonStop S-series Service Provider
Supplement.
Do you wish to continue with this command (Y/[N])?y
If the command is successful, SCF displays:
The switch has received the configuration file which will be put into use
after the next HARD RESET command. A SOFT RESET may be used instead if the
"Hardware Data ID" field in the STATUS SWITCH display indicates "match".
This example downloads the FPGA file $SYSTEM.SYS05.LBC2819 to the switch on
the external ServerNet Y fabric in zone 3, layer 2:
> LOAD SWITCH $ZZSMN, FABRIC Y, ZONE 3, LAYER 2, FPGA $SYSTEM.SYS05.LBC2819
This command should only be issued by Hewlett-Packard trained support
personnel. Executing this command will load a new FPGA image on the switch.
Before executing this command, be sure to read the instructions for switch
FPGA download in the NonStop S-series Service Provider Supplement.
Do you wish to continue with this command (Y/[N])?y
If the command is successful, SCF displays:
The switch has received the FPGA file which will be put into use after the
next HARD RESET command.