ServerNet Cluster 6780 Operations Guide (G06.28+, H06.05+)
SCF Commands for the External ServerNet SAN 
Manager Subsystem
ServerNet Cluster 6780 Operations Guide—525606-003
5-38
STATUS SWITCH Command Example
Last Hard Rset 
indicates the time (in Greenwich mean time) of the last hard reset command.
Last Soft Rset 
indicates the time (in Greenwich mean time) of the last soft reset command.
Soft Reset SrcSNID 
is the ServerNet ID of the client that issued a soft reset command if the last reset 
command was a soft reset.
Hardware Data ID 
indicates whether the previous hardware data identifier (HDI) matches the loaded 
HDI after a soft reset.
Firmware Exception 
indicates the last cause, if any, of a firmware exception that induced a soft reset.
Firmware Image A 
indicates the condition of the firmware stored in Image A of the switch. Two images 
are stored for fault tolerance. Possible values are ok, CRC ERROR, and UNKNOWN.
Firmware Image B 
indicates the condition of the firmware stored in Image B of the switch. Two images 
are stored for fault tolerance. Possible values are ok, CRC ERROR, and UNKNOWN.
FPGA Image A 
indicates the condition of the Field-Programmable Gate Array (FPGA) stored in 
Image A of the switch. Two images are stored for fault tolerance. Possible values 
are ok, CRC ERROR, and UNKNOWN.
FPGA Image B 
indicates the condition of the Field-Programmable Gate Array (FPGA) stored in 
Image B of the switch. Two images are stored for fault tolerance. Possible values 
are ok, CRC ERROR, and UNKNOWN.
Config Image A 
indicates the condition of the configuration stored in Image A of the switch. Two 
images are stored for fault tolerance. Possible values are ok, CRC ERROR, and 
UNKNOWN.