ServerNet Cluster 6780 Operations Guide (G06.28+, H06.05+)

SCF Commands for the External ServerNet SAN
Manager Subsystem
ServerNet Cluster 6780 Operations Guide525606-003
5-41
STATUS SWITCH, ONLY, CRU Command Example
STATUS SWITCH, ONLY, CRU Command Example
This example shows the STATUS SWITCH command with the ONLY and CRU options:
> SCF STATUS SWITCH $ZZSMN, ONLY X, CRU 6
STATUS SWITCH X Fabric Y Fabric
|----------------------------------------------------------------------------|
| Response Status | ok | |
| Rsp Status Detail | No Status Detail | |
|--------------------|---------------------------|---------------------------|
| Switch Type | Model 6780 | |
| Switch Zone | 1 | |
| Switch Layer | 2 | |
| | | |
| CRU Slot | 6 | |
| CRU Type | Dual SMF | |
| CRU State | enabled | |
| CRU Fault LED | off | |
| | | |
| Transceiver 1 | 9/125u SMF | |
| Transceiver Enabled| yes | |
| Transceiver Status | ok | |
| Link Alive LED | on | |
| Optical Signal | present | |
| | | |
| Transceiver 2 | 9/125u SMF | |
| Transceiver Enabled| yes | |
| Transceiver Status | ok | |
| Link Alive LED | OFF | |
| Optical Signal | LOST | |
|--------------------|---------------------------|---------------------------|
In this example:
Response Status
is the general condition of the connection. For a list of possible values, see
Response Status Enumeration on page 5-53.
Rsp Status Detail
is the specific condition of the connection. For a list of possible values, see
Response Status Detail Enumeration on page 5-53
Switch Type
is the type of switch as indicated by the switch model number.
Switch Zone
is the zone within the layered topology where the switch is located. Possible values
are 1, 2, or 3.
Switch Layer
is the layer within the switch zone. Possible values are 1, 2, 3, or 4.
CRU Slot
is the slot number of the specified CRU.