ServerNet Cluster 6780 Operations Guide (G06.28+, H06.05+)
SCF Commands for the External ServerNet SAN 
Manager Subsystem
ServerNet Cluster 6780 Operations Guide—525606-003
5-45
STATUS SWITCH, ROUTER Command Example
CRU S,P
is the slot number (S) and port number (P) of the switch PIC to which the router 
port is connected. For a router interconnect PIC, only the slot number appears 
because it has no ports.
Port Neighbor Data 
contains information about the neighbor port, if it is a connected external port. The 
Port Neighbor Data section of the display appears multiple times if there are 
multiple zones and layers in the cluster. The neighbor port information includes: 
Router Port
is the neighbor router port number.
Firmware Revision
is the version of firmware loaded on the 6780 switch
Numeric Selector
is the numeric selector setting of the 6780 switch
Neighbor Check
is the type of neighbor check to be performed to enable the port. For possible 
values, see Table 5-2, Neighbor Checks.
Expt|Recv CRU S,P
is the expected and received values for the CRU slot (S) and port (P) numbers 
of the neighbor. The first column contains the expected values, and the 
second column contains the actual values received.
Expt|Recv Conf Ver
is the expected and received version of the neighbor configuration. The first 
column contains the expected configuration version, and the second column 
contains the actual configuration version received.
Expt|Recv Conf Tag
is the expected and received configuration tag of the neighbor. The first 
column contains the expected configuration tag, and the second column 
contains the actual configuration tag.
Expt|Recv Conf Rev
is the expected and received configuration revision of the neighbor. The first 
column contains the expected configuration revision, and the second column 
contains the actual configuration revision received.