ServerNet Cluster 6780 Operations Guide (G06.28+, H06.05+)
SCF Error Messages
ServerNet Cluster 6780 Operations Guide—525606-003
6-5
ServerNet Cluster (SCL) Error Messages
Recovery. Verify the database record using the SCF INFO command. If necessary, 
reload the system using a saved version of the system configuration database. If the 
problem persists, contact your service provider. (See If You Have to Call Your Service 
Provider on page 6-20.)
SCL Error 00009
reason-text
is a text string that describes the reason the processor switch failed.
Cause. A processor switch was not performed. The process pair continues to execute 
in the current processors.
Effect. The command is not executed. SCF waits for the next command.
Recovery. Verify the processors used by the ServerNet cluster monitor process. Retry 
the command if necessary.
SCL Error 00010
Cause. The MSGMON process does not exist. The probable cause is that the 
processor hosting the MSGMON process is not running.
Effect. The command is not executed. SCF waits for the next command.
Recovery. Check that the processor hosting the MSGMON process is loaded. Then 
reissue the command.
SCL Error 00011
Cause. The ServerNet cluster subsystem failed to initiate START processing. 
Effect. The command is not executed. SCF waits for the next command.
Recovery. Check that ServerNet cables are connected from the node to the 
ServerNet II Switch. The subsystem cannot be started until the cables are connected 
and the external system area network (SAN) manager process (SANMAN) has 
communicated with the ServerNet II Switch. Check the event logs for error messages. 
Once you have resolved any problems, reissue the command.
SCL E00009 Processor switch failed, reason-text.
SCL E00010 MsgMon process does not exist.
SCL E00011 Subsystem start failure.