ServerNet Cluster 6780 Operations Guide (G06.28+, H06.05+)

ServerNet Cluster 6780 Operations Guide525606-003
B-1
B
Cable Connections in a Layered
Topology
This appendix list the cable connections between cluster switches in a layered
topology. For more detail on cabling, see the ServerNet Cluster 6780 Planning and
Installation Guide.
Connections between the layers within a zone appear in Table B-1.
Connections between two zones appear in Table B-2 and Table B-3.
Connections for three zones appear in Table B-4 and Table B-5
Handling Fiber-Optic Cables
Labeling Cables
If you need to replace a cable between switches, be sure to clearly label it to identify its
connection.
On each label, include the fabric, zone, and layer of the switch, and the slot number,
and port number the cable will be connected to. For example: switch X12, slot 12, port
1 one end of the cable and switch X14, slot 12, port 1 on the other end.
Caution. When connecting the cables:
Handle the fiber-optic cables gently. Do not step on a fiber-optic cable or place a heavy
object on top of a fiber-optic cable.
If the cable must be installed with a bend, make sure the bend radius is not smaller than
16 inches (3-4 mm).