ServerNet Cluster 6780 Operations Guide (G06.28+, H06.05+)
Troubleshooting and Replacement Procedures
ServerNet Cluster 6780 Operations Guide—525606-003
3-35
Diagnosing Performance Problems
1. Remove the power supply. 
2. Wait at least five seconds and then install a replacement power supply in the same 
slot. Be sure it is fully seated.
3. Wait for power LED to light. Be sure the fault LED does not light.
Diagnosing Performance Problems
Diagnosis of performance problems in any environment involves multiple steps and 
requires extensive knowledge of performance fundamentals and methodologies. If 
there are ServerNet Cluster performance issues, you might want to explore these 
areas:
•
Throughput: How much traffic is flowing through nodes and between individual 
processors?
•
Latency: How well does traffic flow?
•
Problem isolation: What is responsible for the problem?
The Measure performance tool can assist you in collecting data for throughput and 
latency analysis. Measure has a SERVERNET entity that tracks all the interprocessor 
communication for remote nodes (remote IPC type). This information allows you to 
isolate and examine the flow of ServerNet cluster traffic. Another area to investigate, if 
you suspect performance degradation, is the health of your Expand lines. For more 
information on the SERVERNET, NETLINE, and PROCESS entities and the counters 
added specifically for ServerNet cluster support, consult the Measure Reference 
Manual. 