ServerNet Cluster 6780 Operations Guide (G06.28+, H06.05+)
SCF Commands for SNETMON and the ServerNet 
Cluster Subsystem
ServerNet Cluster 6780 Operations Guide—525606-003
4-2
SCF Objects for ServerNet Cluster
SCF Objects for ServerNet Cluster
These SCF objects are supported for SNETMON and the ServerNet cluster (SCL) 
subsystem:
Sensitive and Nonsensitive Commands
Sensitive SCF commands can have detrimental effects if improperly used. A sensitive 
command can be issued only by:
•
The super ID
•
The owner of the subsystem 
•
A member of the group of the subsystem owner
When used in conjunction with the security features of the system services, SCF 
provides effective access control for sensitive commands. Commands that request 
information or status but do not affect operation are called nonsensitive commands and 
are available to all users.
Summary States for the SCL SUBSYS Object
The ServerNet cluster (SCL) subsystem state is maintained by the ServerNet cluster 
monitor process (SNETMON). There is no aggregate ServerNet cluster subsystem 
state. Each ServerNet cluster monitor process maintains the state of objects relevant to 
the local system and its connection to the ServerNet cluster. Table 4-2
 lists the 
summary states for the SUBSYS object supported by the SCL subsystem.
PROCESS Use this object to issue commands for SNETMON ($ZZSCL).
SUBNET Use this object to gather information about connections within 
the ServerNet cluster subsystem ($ZZSCL).
SUBSYS Use this object to issue commands for the ServerNet cluster 
subsystem itself ($ZZSCL).