ServerNet Cluster 6780 Operations Guide (G06.29+, H06.06+, J06.03+)
SCF Commands for the External ServerNet SAN
Manager Subsystem
ServerNet Cluster 6780 Operations Guide—525606-004
5-8
DUMP SWITCH Command
DUMP SWITCH Command
The DUMP SWITCH command copies a memory image from a 6780 switch to a
specified file on the local system.
The DUMP SWITCH command syntax is:
OUT file-spec
causes any SCF output generated for this command to be directed to the specified
file.
FABRIC { X | Y } | NEAREST { X | Y }
specifies the external ServerNet fabric of the local cluster switch from which you
want to copy a memory image. NEAREST and FABRIC are synonymous in this
case, and either can be used. The local switch is the one directly connected to the
node where you issue this command.
FABRIC { X | Y } , ZONE znum , LAYER lnum
is a string of identifiers used to specify the switch from which you want to copy a
memory image.
FABRIC { X | Y } specifies the external ServerNet fabric.
ZONE znum specifies the cluster switch zone. znum must be in the range 1
through 3.
LAYER lnum specifies the cluster switch layer. lnum must be in the range 1
through 4.
TO filename
specifies the file to receive the memory image. filename must be a file on the
local system.
SAVED
specifies that the memory image saved by firmware (as a result of a runtime error)
be collected.
DUMP [ / OUT file-spec / ] SWITCH $ZZSMN
{ , FABRIC { X | Y } |, NEAREST { X | Y } }
{ , FABRIC { X | Y }, ZONE znum , LAYER lnum }
, TO filename
{ , SAVED | , ONLINE [ , FORCED ] }