ServerNet Cluster 6780 Operations Guide (G06.29+, H06.06+, J06.03+)
SCF Commands for the External ServerNet SAN
Manager Subsystem
ServerNet Cluster 6780 Operations Guide—525606-004
5-20
INFO SWITCH Command Example
Image A VPROC (FPGA)
is the VPROC string for the version of the FPGA stored in image A on the cluster
switch.
Image B VPROC (FPGA)
is the VPROC string for the version of the FPGA stored in image B on the cluster
switch.
Config Version ID
is the version of the configuration running on the cluster switch.
Config Revision
is the switch configuration revision, where the upper two bytes reflect the major
revision and the lower two bytes represent the minor revision.
Config HDI
is the hardware data identifier (HDI) for the switch 3 configuration file.
Config Tag
is a numeric representation of the configuration tag stored on the cluster switch.
The configuration tag varies depending on the ServerNet cluster topology and the
location of the switch within it.
Config VPROC
is the VPROC string for the version of the configuration running on the cluster
switch. The VPROC string is truncated in this display. To see the full VPROC
string, use the OSM Service Connection.
Image A VPROC (configuration)
is the VPROC string for the version of the configuration stored in image A on the
cluster switch.
Image B VPROC (configuration)
is the VPROC string for the version of the configuration stored in image B on the
cluster switch.
CRU Slot (nn)
indicates the types of CRUs installed in slots 01 through 18 of the 6780 switch. For
a listing of the CRU types for the 6780 switch, see Table 5-3, CRU Slots for the
6780 Switch, on page 5-16.
If there is no CRU installed in the slot, ABSENT appears.
If the wrong CRU is installed in the slot, WRONG TYPE appears.