ServerNet Cluster 6780 Operations Guide (G06.29+, H06.06+, J06.03+)

ServerNet Cluster 6780 Operations Guide525606-004
6-1
6 SCF Error Messages
This section describes the types of error messages generated by SCF and provides
the cause, effect, and recovery information for the SCF error messages specific to the
ServerNet cluster subsystem and the external system area network manager process
(SANMAN).
This section includes these main topics:
Types of SCF Error Messages
Command Parsing Error Messages
Command parsing error messages are generated when a command is being broken
down into its component parts. These error messages have no associated error
number and are generally self-explanatory. For example:
Expecting an existing SCF supported object name
Expecting an SCF command or a program file
Numbered Error Messages That SCF Generates
SCF generates numbered error messages that begin at 20000. For example:
SCF E20211 Invalid object type
Common Error Messages
SCF provides a pool of error messages, called common errors, that can be used by all
subsystems. These errors always have negative error numbers. Each error message is
preceded by the name of the subsystem in which the error is encountered and a
character type code (E for critical or W for noncritical). For example:
SCL E-00005 Command is not supported by this subsystem
SCL Subsystem-Specific Error Messages
Error messages specific to the ServerNet cluster subsystem are generated by and
pertain solely to the ServerNet cluster subsystem. These errors always have positive
error numbers.
Heading Page
Types of SCF Error Messages
6-1
ServerNet Cluster (SCL) Error Messages 6-2
SANMAN (SMN) Error Messages 6-8
If You Have to Call Your Service Provider 6-20