ServerNet Cluster 6780 Operations Guide (G06.29+, H06.06+, J06.03+)
Troubleshooting and Replacement Procedures
ServerNet Cluster 6780 Operations Guide—525606-004
3-22
Checking the Internal ServerNet X and Y Fabrics
The system displays:
In this example, the boldface type shows that the Y-fabric connection between the 
processors in group 01 (processors 0 and 1) and the processors in group 03 
(processors 4 and 5) is down. The X fabric is functioning normally. 
For more information about the STATUS SERVERNET command, refer to the SCF 
Reference Manual for the Kernel Subsystem.
NONSTOP KERNEL - Status SERVERNET
X-FABRIC
 TO 0 1 2  3 4  5 6  7 8 9 10 11 12 13 14 15
FROM
 00  UP UP UP  UP UP UP UP UP UNA UNA UNA UNA UNA UNA UNA UNA
 01  UP UP UP  UP UP UP UP UP UNA UNA UNA UNA UNA UNA UNA UNA
 02  UP UP UP  UP UP UP UP UP UNA UNA UNA UNA UNA UNA UNA UNA
 03  UP UP UP  UP UP UP UP UP UNA UNA UNA UNA UNA UNA UNA UNA
 04  UP UP UP  UP UP UP UP UP UNA UNA UNA UNA UNA UNA UNA UNA
 05  UP UP UP  UP UP UP UP UP UNA UNA UNA UNA UNA UNA UNA UNA
 06  UP UP UP  UP UP UP UP UP UNA UNA UNA UNA UNA UNA UNA UNA
 07  UP UP UP  UP UP UP UP UP UNA UNA UNA UNA UNA UNA UNA UNA
 08 <- DOWN
 09 <- DOWN
 10 <- DOWN
 11 <- DOWN
 12 <- DOWN
 13 <- DOWN
 14 <- DOWN
 15 <- DOWN
Y-FABRIC
 TO 0 1 2  3 4  5 6  7 8 9 10 11 12 13 14 15
FROM
 00  UP UP UP  UP DN DN UP UP UNA UNA UNA UNA UNA UNA UNA UNA
 01  UP UP UP  UP DN DN UP UP UNA UNA UNA UNA UNA UNA UNA UNA
 02  UP UP UP  UP UP UP UP UP UNA UNA UNA UNA UNA UNA UNA UNA
 03  UP UP UP  UP UP UP UP UP UNA UNA UNA UNA UNA UNA UNA UNA
 04  DN DN UP  UP UP UP UP UP UNA UNA UNA UNA UNA UNA UNA UNA
 05  DN DN UP  UP UP UP UP UP UNA UNA UNA UNA UNA UNA UNA UNA
 06  UP UP UP  UP UP UP UP UP UNA UNA UNA UNA UNA UNA UNA UNA
 07  UP UP UP  UP UP UP UP UP UNA UNA UNA UNA UNA UNA UNA UNA
 08  <- DOWN
 09 <- DOWN
 10 <- DOWN
 11 <- DOWN
 12 <- DOWN
 13 <- DOWN
 14 <- DOWN
 15 <- DOWN