ServerNet Cluster 6780 Planning and Installation Guide (G06.24+, H06.03+)

Using the Long-Distance Option
ServerNet Cluster 6780 Planning and Installation Guide527301-004
G-2
Hardware Requirements
Hardware Requirements
To use the long-distance option, your cluster must meet these hardware requirements:
All processors on all NonStop S-series servers in the cluster must be S76000,
S86000, or later.
The cluster must be built with 6780 switches.
Zone-to-zone connections between 5 and 15 km can use either single-mode fiber-
optic cables or Dense Wave Division Multiplexers (DWDMs). A DWDM can
transmit multiple optical signals over a single fiber-optic connection and extend
optical signal strength.
If DWDMs are used, the connections between the 6780 switches and the DWDMs
must be single-mode fiber-optic cables.
Note. If DWDMs are not used, these requirements apply:
Your service provider must perform margin testing on the transceivers used for long-
distance connections that are between 10 and 15 km.
The margin test requires an attenuator fiber cable which can be ordered with the long-
distance option.
For more information on the margin test and its requirements, your service provider should
refer to hardware technical bulletin TB20041.