Task 7: Plan for the Fiber-Optic Cables
Table 3-11 on page 3-17 describes the required fiber-optic cables. 
Table 3-11. Type and Length of Cables Required for Clustering
Fiber-Optic 
Cable Type
Maximum Distance 
Supported   Connects From: Connects To:
SMF with SC to 
LC connectors
(NonStop 
S-series servers 
only)
Up to 80 meters
Because of the hardware 
implementation of the 
ServerNet protocol in the 
links between a cluster 
switch and each node, 
this distance is less than 
the distance that SMF 
can support. 
SC connector 
NonStop S-series 
server
X fabric 
Group 01 
Slot 51 (MSEB)
Port 6
Y fabric 
Group 01 
Slot 52 (MSEB)
Port 6
LC connector 
6780 Switch
Slots: 6, 7, 8, or 9
Ports: 1 or 2 
SMF with LC 
connectors
Up to 5 kilometers 
between zones if all 
processors in the 
ServerNet cluster are 
S76000, S86000, or 
later. 
Up to 1 kilometer 
between zones if any 
other type of processor 
is included in the 
ServerNet cluster
See note at end of this 
table regarding longer 
distance connections.
One zone
6780 switch  
Slots: 2 or 3 
Ports: 1 or 2 
Another zone
6780 switch 
Slots: 2 or 3 
Ports: 1 or 2 
MMF with LC 
connectors
Up to 200 meters 
between zones
One zone
6780 switch  
Slots: 2 or 3 
Ports: 1 or 2
Another zone
6780 switch 
Slots: 2 or 3 
Ports: 1 or 2 
Up to 100 meters 
between layers
One layer
6780 switch  
Slots: 11, 12, or 13 
Ports: 1 through 4 
Another layer
6780 switch 
Slots: 11, 12, or 13 
Ports: 1 through 4 
Note: A long-distance option for connections between zones is available. This option affects 