Checking the Internal ServerNet X and Y Fabrics
h. If the action failed, click Show detail for more information.
Checking the Internal ServerNet X and Y Fabrics
Perform this procedure if a problem occurs on an internal fabric on any node in the
ServerNet cluster. You can use the OSM Service Connection or SCF to check the
internal ServerNet fabrics.
1. Using the OSM Service Connection:
a. Check for alarms and repair actions for the Internal Fabric resource. Refer to
OSM online help.
b. If you continue to have a problem, check the integrity of group-to-group
connections along one internal ServerNet fabric at a time. Refer to Using the
Group Connectivity ServerNet Path Test Action on page 8-17.
c. From the OSM Service Connection, check the tree pane to see if the problem
has been resolved.
2. If you continue to have a problem, check the internal ServerNet X and Y fabrics for
the local node. Refer to the STATUS SERVERNET $ZSNET command in the SCF
Reference Manual for the Kernel Subsystem.
3. If you continue to have a problem, refer to:
ServerNet Cluster 6780 Operations Guide
NonStop S-Series Operations Guide
Using the Group Connectivity ServerNet Path Test Action
For NonStop S-series servers, this action checks these components and can often
correct any problems with:
ServerNet cables
PMF CRUs
IOMF CRUs
SEBs and MSEBs in NonStop S-series servers
1. Log on to the OSM Service Connection.
2. Expand the System resource.
3. Right-click the Internal ServerNet X Fabric or Internal ServerNet Y Fabric.
4. From the Available Actions drop-down list, select Group Connectivity ServerNet
Path Test action.
5. Click Perform Action.