ServerNet Cluster 6780 Planning and Installation Guide (G06.28+, H06.05+)

Table Of Contents
Using the Long-Distance Option
ServerNet Cluster 6780 Planning and Installation Guide527301-005
G-7
Hardware Installation
Setting the Numeric Selectors
Follow the guidelines in Task 3: Set the Numeric Selector on page 5-4, but do not use
the numeric selector settings described there.
Instead, set the numeric selectors for the switches to the values shown in Table G-3.
These settings are reserved for long-distance configurations and can be used only if all
the required software components in Table G-1 or Table G-2 are installed.
Note. You must set the numeric selectors on all switches in the cluster to the values shown in
Ta ble G-3 so that all switches are recognized.
Table G-3. Numeric Selector Settings for the Long-Distance Option
6780
Switch Fabric Zone Layer
Numeric
Selector
X11 X 1 1 1411
X12 X 1 2 1412
X13 X 1 3 1413
X14 X 1 4 1414
X21 X 2 1 1421
X22 X 2 2 1422
X23 X 2 3 1423
X24 X 2 4 1424
X31 X 3 1 1431
X32 X 3 2 1432
X33 X 3 3 1433
X34 X 3 4 1434
Y11 Y 1 1 1511
Y12 Y 1 2 1512
Y13 Y 1 3 1513
Y14 Y 1 4 1514
Y21 Y 2 1 1521
Y22 Y 2 2 1522
Y23 Y 2 3 1523
Y24 Y 2 4 1524
Y31 Y 3 1 1531
Y32 Y 3 2 1532
Y33 Y 3 3 1533
Y34 Y 3 4 1534