ServerNet Cluster 6780 Planning and Installation Guide (G06.28+, H06.05+)
Table Of Contents
- What’s New in This Guide
- About This Guide
- 1 ServerNet Cluster Overview
- 2 ServerNet Cluster Hardware Description
- 3 Planning for Installation and Migration
- Planning Checklist
- Software Installation Planning
- Hardware Installation and Migration Planning
- Task 1: Plan for the ServerNet Nodes
- Task 2: Plan for the System Consoles
- Task 3: Plan for the 6780 Switches
- Task 4: Plan for the Racks
- Task 5: Plan for the Power Requirements
- Task 6: Plan the Location of the Hardware
- Task 7: Plan for the Fiber-Optic Cables
- Task 8: Plan to Migrate the ServerNet Nodes From 6770 Switches
- Task 9: Plan the ServerNet Node Numbers
- Task 10: Plan the Expand-Over-ServerNet Lines
- Migration Examples
- 4 Preparing a System for Installation or Migration
- 5 Installing 6780 Switches
- 6 Connecting the Fiber-Optic Cables
- Summary of Tasks
- Handling the Fiber-Optic Cables
- Connecting the Layer Cables
- Connecting the Zone Cables
- Connecting the Cables Between a Node and a 6780 Switch
- Alerts
- Task 1: Double-Check the Required Software and Hardware
- Task 2: Label the Cables That Connect to the Node
- Task 3: Inspect the Cables
- Task 4: Connect a Cable to the Switch
- Task 5: Connect a Cable to the Node
- Task 6: Check the Link-Alive LEDs
- Task 7: Check Operations
- Task 8: Finish Connecting the Fiber-Optic Cables
- Routing the Fiber-Optic Cables
- 7 Configuring Expand-Over-ServerNet Lines
- Using Automatic Line-Handler Generation
- Using the OSM Service Connection
- Using SCF
- Rule 1: Configure the Primary and Backup Line-Handler Processes in Different Processor Enclosures
- Rule 2: For Nodes With 6 or More Processors, Avoid Configuring the Line-Handler Processes in Proc...
- Rule 3: For Nodes With More Than 10 Processors, Avoid Configuring the Line-Handler Processes in P...
- Expand-Over-ServerNet Line-Handler Process Example
- 8 Checking Operations
- Checking the Operation of the ServerNet Cluster
- Checking the Operation of Each Switch
- Checking the Power to Each Switch
- Checking the Switch Components
- Checking the Numeric Selector Setting
- Checking the Globally Unique ID (GUID)
- Checking for a Mixed Globally Unique ID (GUID)
- Checking the Fiber-Optic Cable Connections to the Switch Port
- Checking the Switch Configuration, Firmware, and FPGA Images
- Checking the Operation of Each Node
- Checking the Service Processor (SP) Firmware
- Checking That Automatic Line-Handler Generation Is Enabled
- Checking the ServerNet Node Numbers
- Checking MSGMON, SANMAN, and SNETMON
- Checking for Alarms on Each Node
- Checking the ServerNet Cluster Subsystem
- Checking That the ServerNet Node Numbers Are Consistent
- Checking Communications Between a Local Node and a Switch
- Checking Communications With a Remote Node
- Checking the Internal ServerNet X and Y Fabrics
- Checking the Operation of Expand Processes and Lines
- 9 Changing a ServerNet Cluster
- OSM Actions
- Removing a Node From a ServerNet Cluster
- Removing Switches From a ServerNet Cluster
- Adding a Node to a ServerNet Cluster
- Adding a Switch Layer to a ServerNet Cluster
- Adding a Switch Zone to a ServerNet Cluster
- Task 1: Prepare to Add the Switches
- Task 2: Connect the Cables Between Layers
- Task 3: Check Operations
- Task 4: Disconnect the Cables Between Zones
- Task 5: Connect the Cables Between Zones
- Task 6: Check Operations
- Task 7: Connect the Additional Nodes
- Task 8: Check Operations
- Task 9: Repeat Tasks 2 Through 8 for the Other Fabric
- Task 10: Reenable OSM Alarms
- Moving a Node
- Changing the Hardware in a Node Connected to a ServerNet Cluster
- 10 Troubleshooting
- Symptoms
- Recovery Operations
- Enabling Automatic Expand-Over-ServerNet Line-Handler Generation
- Reseating a Fiber-Optic Cable
- Correcting a Mixed Globally Unique ID (GUID)
- Restoring Connectivity to a Node
- Switching the SANMAN Primary and Backup Processes
- Switching the SNETMON Primary and Backup Processes
- Configuring the Expand-Over-ServerNet Line-Handler Processes and Lines
- Starting Required Processes and Subsystems
- Fallback Procedures
- 11 Starting and Stopping ServerNet Cluster Processes and Subsystems
- A Part Numbers
- B Blank Planning Forms
- C ESD Guidelines
- D Specifications
- E Configuring MSGMON, SANMAN, and SNETMON
- F Updating the 6780 Switch Logic Board Firmware, Configuration, and FPGA Images
- G Using the Long-Distance Option
- Safety and Compliance
- Glossary
- Index

Glossary
ServerNet Cluster 6780 Planning and Installation Guide—527301-005
Glossary-13
IOMF CRU
enclosure is identical to a processor enclosure except that it contains I/O multifunction
(IOMF) CRUs instead of processor multifunction (PMF) CRUs.
IOMF CRU. See I/O multifunction (IOMF) CRU.
I/O multifunction (IOMF) CRU. (1) A NonStop S-series customer-replaceable unit (CRU)
that connects an I/O enclosure to a processor enclosure through a ServerNet cable
and supplies power to the components within the IOMF CRU as well as redundantly to
the disk drives, SCSI terminators, and ServerNet adapters in that enclosure. The IOMF
CRU contains a power supply, a service processor (SP), a ServerNet router, an
Ethernet controller, an external ServerNet port, and three SCSI ServerNet addressable
controllers (S-SACs) in a single unit. (2) A collective term for both IOMF CRUs and
IOMF 2 CRUs when a distinction between the two types of CRUs is not required.
IOP. See input/output process (IOP).
IP. See Internet protocol (IP).
IP address. An address that identifies a specific host to the Internet protocol (IP). An IP
address consists of two parts: a network address, which identifies the network, and a
local address, which identifies a host within a network. A network address is
concatenated with a host address to form the IP address and uniquely identify a host
within a network. IP routes data between source and destination IP addresses.
IPC. See interprocessor communication (IPC).
KB. See kilobyte (KB).
Kernel subsystem. Ithe subsystem for configuration and management of the Subsystem
Control Facility (SCF) subsystem managers that are generic processes, some system
attributes, and the ServerNet X and Y fabrics.
Kernel subsystem manager process. The generic process that starts and manages other
generic processes, some system attributes, and the ServerNet fabrics. The $ZZKRN
Kernel subsystem manager process is started and managed by the $ZPM persistence
manager process. See also generic process.
kilobyte (KB). A unit of measurement equal to 1024 bytes. See also gigabyte (GB),
megabyte (MB), and terabyte (TB).
LAN. See local area network (LAN).
layered topology. The network topology for ServerNet clusters using the HP NonStop
ServerNet Switch (model 6780). The layered topology can scale by adding cluster
switch layers or zones. The layered topology supports up to four layers and three
zones. See also star topologies.
LIF. See logical interface (LIF).