ServerNet Cluster Manual
Installing and Configuring a ServerNet Cluster
ServerNet Cluster Manual—520575-003
3-5
Task 5: Install MSEBs in Slots 51 and 52 of Group
01
For more information about software requirements, refer to Section 2, Planning for
Installation. For software installation information, refer to the following:
•
G06.xx Software Installation and Upgrade Guide
•
NonStop System Console Installer Guide
•
Interactive Upgrade Guide
After upgrading operating system software, be sure to save a stable copy of the current
configuration using the SCF SAVE command. For example:
-> SAVE CONFIGURATION 01.02
This precaution will help you recover from any errors during the configuration of
ServerNet cluster software. For information about the SCF SAVE CONFIGURATION
command, refer to the SCF Reference Manual for G-Series Releases.
Task 5: Install MSEBs in Slots 51 and 52 of Group 01
If you did not install MSEBs as part of hardware planning, you must do so now. You
can install the MSEBs in all the systems now or install them as you add each system to
the cluster.
You can use a guided replacement procedure to replace the SEBs installed in slots 51
and 52 of group 01. This online method requires you to replace one CRU at a time.
You can also use the guided procedure to install or replace a PIC in an MSEB.
To launch the TSM guided procedure, select Start>Programs>HP TSM>Guided
Replacement Tools>Replace SEB or MSEB. The OSM guided procedure is
launched from within the OSM Service Connection by performing the Replace action
from the SEB you want to replace. Online help is available to assist you in performing
the procedures.
You can replace only one SEB or MSEB at a time. Online help is available to assist
you. The online help prompts you to connect ServerNet cables to the PICs in the
MSEB.
Note. The guided procedure for replacing an SEB or MSEB cannot be used to replace
ServerNet/FX or ServerNet/DA adapters installed in group 01, slots 51 and 52. To move the
adapters to an unused slot in the same enclosure or another enclosure, refer to the manual for
each adapter.
Note. Before using the guided procedure to replace an SEB or an MSEB, be sure to review
the online help topic “Read This First.” This topic contains important information about software
requirements and tools you need to perform the procedure. To view the online help, choose
Procedure Help from the Help menu.