ServerNet Cluster Manual

Installing and Configuring a ServerNet Cluster
ServerNet Cluster Manual520575-003
3-6
Task 5: Install MSEBs in Slots 51 and 52 of Group
01
Considerations for Connecting ECL ServerNet Cables to
ECL PICs
If you are connecting ECL ServerNet cables to ECL PICs, note the following
considerations:
The ServerNet cable connector and ECL PIC connector have standoffs that must
be mated correctly. See Figure 3-1.
When possible, connect the cable to the PIC on the MSEB before installing the
MSEB into the slot. Placing the MSEB on its side on a flat surface and then
connecting the cable makes it easier to secure the thumbscrews.
Finger-tighten both thumbscrews on the cable connector at the same time so that
the connector attaches squarely to the PIC.
Figure 3-1. Connecting a ServerNet Cable to an ECL PIC
VST005.vsd
ECL PIC
Standoff
Connector
Standoff
ECL PIC
MSEB
Faceplate
ServerNet Cable
Connector