ServerNet Cluster Manual
Installing and Configuring a ServerNet Cluster
ServerNet Cluster Manual—520575-003
3-17
Task 9: Perform the Guided Procedure for
Configuring a ServerNet Node
9. In the Available Actions list, select Firmware Update and click Perform Action. The
Update Switch guided procedures interface appears.
10. Click Start and follow the guided procedure to download the appropriate firmware.
For online help, click the Help menu or click the Help button in any of the
procedure dialog boxes.
You can ignore local switch and peer fabric errors during this procedure. When the
Perform SCF STATUS SUBNET Command and the SCF START SERVERNET
Command dialog boxes appear, click Continue.
11. After the firmware update procedure is complete, return to the Actions dialog box,
select Configuration Update, and click Perform Action. The Update Switch guided
procedures interface appears again.
12. Click Start and follow the guided procedure to download the appropriate
configuration files. For online help, click the Help menu or click the Help button in
any of the procedure dialog boxes.
You can ignore local switch and peer fabric errors during this procedure. When the
following dialog boxes appear, select the option to continue with the procedure:
•
Perform SCF STATUS SUBNET Command dialog box
•
CAUTION: Possible Cluster Outage dialog box
•
SCF START SERVERNET Command dialog box
13. After the Firmware Update and Configuration Update actions are complete:
a. Disconnect the node from the ServerNet II Switch.
b. Power off the ServerNet II Switch.
c. Power off the UPS.
d. Disconnect the two AC transfer switch power cords from the power sources.
14. Disconnect the cluster switch from the node you selected in Step 1 and go to the
next installation task.
Task 9: Perform the Guided Procedure for Configuring a
ServerNet Node
Use the guided configuration procedure to configure and add a node (system) to a
ServerNet cluster (including the first node in the cluster). You perform this procedure
on one system at a time.
To launch the TSM guided procedure, select Start>Programs>HP TSM>Guided
Replacement Tools>Replace SEB or MSEB. The OSM guided procedure is
Note. Documentation for the guided procedure is contained in the online help for the
procedure. Before using the guided procedure to configure and add a node, be sure to review
the online help topic “Read Before Using.” This topic contains important information about
software requirements that must be met before you run the procedure.