ServerNet Cluster Manual
Installing and Configuring a ServerNet Cluster
ServerNet Cluster Manual—520575-003
3-21
Task 9: Perform the Guided Procedure for
Configuring a ServerNet Node
fail to make a solid connection even though the connector is inserted properly. 
Figure 3-5 shows a fully inserted connector in which one of the fibers does not 
make a solid connection.
7. Check the link-alive LED at both ends of the cable. Both LEDs should light 
seconds after the connector is inserted. You must check the link-alive LED at both 
ends of the cable to ensure that both the transmit and receive fibers are 
connected. It is possible for the link-alive LED to light on one end of the cable even 
though one of the fibers is not connected. See Figure 3-6.
Figure 3-5. Inserted Connector With Bad Fiber Connection
Figure 3-6. Effect of Uneven Fiber Insertion on Link Alive
VST144.vsd
Bad Fiber Connection
VST145.vsd
TxRx
Fibers
Not
Evenly
Inserted
TxRx
Link
Alive
TxRx
Fibers
Evenly
Inserted
Defective ConnectorsGood Connector
Link
Alive
No Link
Alive