ServerNet Cluster Manual
Upgrading a ServerNet Cluster
ServerNet Cluster Manual—520575-003
4-33
Fallback for Upgrading ServerNet Cluster Software
With System Loads to Obtain G06.12 Functionality
In the SCF display, check the “SvNet Node Number” values for the MSEB port 
and switch port to make sure they are the same. If the values are not the 
same, use one of the following recovery measures:
•
Use the SCF PRIMARY PROCESS $ZZSMN command to force a takeover 
of the SANMAN process in the problem node.
•
Disconnect and reconnect the MSEB-to-switch fiber-optic cable on the 
affected fabric.
m. Perform a system load of the down-rev operating system on the downloader 
node.
3. Perform a system load of the down-rev operating system on the next node, and 
continue until you have loaded the down-rev operating system on all desired 
nodes. 