ServerNet Cluster Manual
Troubleshooting and Replacement Procedures
ServerNet Cluster Manual—520575-003
7-29
Checking the External ServerNet X and Y Fabrics
Checking the External ServerNet X and Y Fabrics
You must use the TSM Service Application to check the external ServerNet X and Y 
fabrics. The guided procedure for troubleshooting a ServerNet fabric cannot 
troubleshoot the link between an MSEB and a ServerNet II Switch. The guided 
procedure can troubleshoot internal fabrics only. However, you can perform internal 
and external loopback tests on an NNA PIC in an MSEB.
If no alarms are visible on the external fabrics but you still want to check the 
connectivity between the local node and the cluster switch, you can use the Node 
Connectivity ServerNet Path Test action. This action tests a path from the local 
MSEB to the ServerNet II Switch component on one fabric. If problems are found, TSM 
generates alarms based on the result. This action is provided for diagnostic purposes 
only. It has no destructive effect.
Table 7-4 describes the scope of the Node Connectivity ServerNet Path Test action.
If an alarm is generated, the problem lies between the local node and the cluster 
switch. The problem might be any of the following components:
•
The MSEB in slot 51 or 52 of the group 01 enclosure of the local system.
•
The PIC in port 6 of the MSEB in slot 51 or 52 of the group 01 enclosure of the 
local system.
•
The cable from the PIC in port 6 of the MSEB in slot 51 or 52 of the group 01 
enclosure to the ServerNet II Switch component of the cluster switch.
•
The ServerNet II Switch component of the cluster switch.
•
The PIC in the ServerNet II Switch to which the cable from the local system is 
connected. Note that PICs installed in ServerNet II Switches are not currently 
replaceable. 
Table 7-4. Scope of Node Connectivity ServerNet Path Test
On This 
Fabric The test checks from . . . To the . . .
X fabric Port 6 of the MSEB in slot 51 of group 01 X-fabric ServerNet II Switch 
component, including the 
status of the switch and the 
switch port.
Y fabric Port 6 of the MSEB in slot 52 of group 01 Y-fabric ServerNet II Switch 
component, including the 
status of the switch and the 
switch port.