ServerNet Cluster Manual
SCF Commands for the External ServerNet SAN
Manager Subsystem
ServerNet Cluster Manual—520575-002
9-5
INFO Command
The following example blinks the LEDs on the nearest Y-fabric cluster switch:
> ALTER SWITCH $ZZSMN, NEAREST Y, BLINK ALL
The nearest ServerNet switch in the external ServerNet Y fabric has begun
to blink the LEDs of all ports.
INFO Command
The INFO command obtains information about a cluster switch or about the external
ServerNet fabric connection to the nearest cluster switch. Unless specified otherwise,
information is displayed for both fabrics. This information is returned by the external
ServerNet SAN manager process ($ZZSMN). INFO is a nonsensitive command.
The INFO command syntax is:
OUT file-spec
causes any SCF output generated for this command to be directed to the specified
file.
ONLY fabric-id
displays switch configuration information for only the specified fabric, where
fabric-id is either X or Y.
Consideration
In addition to the values described in the INFO command displays, you might see
values of N/A or UNKNOWN. In general, a value of N/A means that a value is not
applicable or not expected for the field. A value of UKNOWN means that a value is
expected, but cannot be obtained for some reason.
INFO [ /OUT file-spec/ ]{ CONN[ECTION] | SWITCH } $ZZSMN
[, ONLY fabric-id ]