ServerNet Cluster Manual
SCF Commands for the External ServerNet SAN
Manager Subsystem
ServerNet Cluster Manual—520575-002
9-6
INFO CONNECTION Command Example
INFO CONNECTION Command Example
The following example shows the INFO CONNECTION $ZZSMN command:
> INFO CONN $ZZSMN
INFO CONNECTION X Fabric Y Fabric
|--------------------------------------------------------------------------|
| Command Status | OK |OK |
| Status Detail | No Status Detail |No Status Detail |
|--------------------|---------------------------|------------|------------|
| Configuration | MSEB Port | Switch Port | MSEB Port | Switch Port|
|--------------------|-------------|-------------|------------|------------|
| Port Info Valid | TRUE | TRUE | TRUE | TRUE |
| Port Number | 6 | 1 | 6 | 1 |
| Desired Port State | N/A | TX/RX ENBLD | N/A | TX/RX ENBLD|
| Neighbor ID Check | N/A | NO QRY PASS | N/A | NO QRY PASS|
| Node Number Mask | 0x000fc000 | 0x000fc000 | 0x000fc000 | 0x000fc000 |
| Node Routing ID | 0x000d8000 | 0x000d8000 | 0x000d8000 | 0x000d8000 |
| SvNet Node Number | 2 | 2 | 2 | 2 |
| NNA Version | 22 | N/A | 22 | N/A |
| PIC Functional ID | NNA PIC | SMF OPTICAL | NNA PIC | SMF OPTICAL|
|--------------------|-------------|-------------|------------|------------|
In this example:
Command Status
is the general condition of the connection. For a list of possible values, see
Command Status Enumeration on page 9-37.
Status Detail
is the specific condition of the connection. For a list of possible values, see Status
Detail Enumeration on page 9-37
Port Info Valid
indicates whether the port information is valid. Possible values are TRUE and
FALSE.
Port Number
is the connector location on the MSEB or cluster switch to which the fiber-optic
ServerNet cable is attached. Valid port numbers on the cluster switch are 0 through
11. The only valid port number on the MSEB is port 6.
Desired Port State
indicates whether transmit and receive are to be enabled. Valid states are:
TX/RX DSBLD
transmit and receive are disabled.