ServerNet Cluster Manual
SCF Commands for the External ServerNet SAN
Manager Subsystem
ServerNet Cluster Manual—520575-002
9-7
INFO CONNECTION Command Example
TX/RX ENBLD
transmit and receive are enabled.
TX/RX AUTO
no low-level neighbor checks are run. The port can still enable or disable
ServerNet traffic.
N/A
does not apply.
Neighbor ID Check
indicates the type of neighbor checks to be performed to enable the port. Possible
values are:
NO QRY PASS
perform no query of neighbor and assume it passes.
NO QRY FAIL
perform no query of neighbor and assume it fails.
IGNORE RSLT
query neighbor, but ignore result.
QRY TO PASS
query neighbor and enable port only if it passes.
Node Number Mask
is a bit-mask indicating which bits of the node routing ID are valid.
Node Routing ID
is the node number routing ID. For the MSEB, the ID is configured on the NNA
PIC. For the cluster switch port, the ID is assigned by the external fabric.
SvNet Node Number
is a number in the range 1 through 24 that identifies a member system in a
ServerNet cluster. The ServerNet node number is a simplified expression of the
six-bit node-routing ID that determines the node to which a ServerNet packet is
routed. The ServerNet node number is assigned based on the port to which the
node is connected on the ServerNet II Switch.