ServerNet Cluster Manual
SCF Commands for the External ServerNet SAN 
Manager Subsystem
ServerNet Cluster Manual—520575-002
9-9
INFO SWITCH Command Example
INFO SWITCH Command Example
The following example shows the INFO SWITCH $ZZSMN command: 
> INFO SWITCH $ZZSMN
  INFO SWITCH      X Fabric       Y Fabric
|----------------------------------------------------------------------------|
| Command Status   | OK         | OK         |
| Status Detail   | No Status Detail    | No Status Detail     |
|--------------------|---------------------------|---------------------------|
| Configuration  |   ServerNet Switch  |  ServerNet Switch   |
|--------------------|---------------------------|---------------------------|
| Switch Locator  | Left switch in room 1205 | Room 1205 Left Side   |
|  "   "    |          |           |
|        |          |           |
| Eye Catcher    | SN         | SN         |
| Manufacturer ID | 0x0053      | 0x0053      |
| Manufacturer Model | ServerNet II    | ServerNet II    |
| Hardware Revision | 0_04      | 0_04       |
| Firmware Revision | 3_0_81      | 3_0_81       |
| Firmware VPROC  | T0569G06^11APR01^FMW^AAE | T0569G06^11APR01^FMW^AAE |
| Globally Unique ID | V0XY35      | V0XY1U       |
| PWA Number   | 425655      | 425655      |
| Conf Support Flags | Status,OS Hints,Tag Pairs | Status,OS Hints,Tag Pairs |
| Number of Ports  | 12         | 12         |
|        |          |           |
| Capability Flag | Can Source And Sink Pkts | Can Source And Sink Pkts |
|  "   "  | Supplies Per Port Data  | Supplies Per Port Data  |
|  "   "  | Full Pkt Wormhole IBC  | Full Pkt Wormhole IBC  |
|  "   "  | Packet Level IBC   | Packet Level IBC   |
|  "   "    | Able To Route Packets  | Able To Route Packets  |
|        |          |           |
| Position ID   | 2        | 2        |
| Topology   | 16-Nodes     | 16-Nodes      |
| Configuration Tag | 0x00010001     | 0x00010001     |
| Config Revision | 0x0001000b     | 0x0001000b     |
| Config VPROC  | T0569G06^02JUL01CL2^AAE | T0569G06^02JUL01CL2^AAE  |
|        |          |           |
| PIC Func ID (00) | SMF Optical PIC Installed | SMF Optical PIC Installed |
| PIC Func ID (01) | SMF Optical PIC Installed | SMF Optical PIC Installed |
| PIC Func ID (02) | SMF Optical PIC Installed | SMF Optical PIC Installed |
| PIC Func ID (03) | SMF Optical PIC Installed | SMF Optical PIC Installed |
| PIC Func ID (04) | SMF Optical PIC Installed | SMF Optical PIC Installed |
| PIC Func ID (05) | SMF Optical PIC Installed | SMF Optical PIC Installed |
| PIC Func ID (06) | SMF Optical PIC Installed | SMF Optical PIC Installed |
| PIC Func ID (07) | SMF Optical PIC Installed | SMF Optical PIC Installed |
| PIC Func ID (08) | SMF Optical PIC Installed | SMF Optical PIC Installed |
| PIC Func ID (09) | SMF Optical PIC Installed | SMF Optical PIC Installed |
| PIC Func ID (10) | SMF Optical PIC Installed | SMF Optical PIC Installed |
| PIC Func ID (11) | SMF Optical PIC Installed | SMF Optical PIC Installed |
|        |          |           |
| ServerNet ID  | 0x000ffffe     | 0x000ffffe     |
| Fabric Setting  | X Fabric     | Y Fabric      |
| Switch Poll Intrvl | 60 seconds      | 60 seconds       |
|--------------------|---------------------------|---------------------------|
| Configuration  |    UPS    |    UPS    |
|--------------------|---------------------------|---------------------------|
| UPS Info Valid  | TRUE       | TRUE       |
| UPS Type   | UPS 1440 VA FW -0039  | UPS 1440 VA FW -0039  |
| UPS ID    | TS392A0114     | TS262A0122     |
| UPS Part Number  | 05144717-5901    | 05144717-5901    |
| UPS Poll Interval | 60 seconds     | 60 seconds     |
|--------------------|---------------------------|---------------------------|
Total Errors = 0 Total Warnings = 0