ServerNet Cluster Manual

SCF Commands for the External ServerNet SAN
Manager Subsystem
ServerNet Cluster Manual520575-002
9-12
INFO SWITCH Command Example
Config Revision
is the revision of the configuration data installed on the cluster switch.
Config VPROC
is the VPROC string for the version of configuration data running on the cluster
switch.
PIC Func ID (xx)
is the type of plug-in card (PIC) installed in the ServerNet II Switch subcomponent
of the cluster switch and the port number in which the PIC is installed. Possible
values are:
SMF Optical PIC Installed
MMF Optical PIC Installed
Serial Copper PIC Installed
ECL PIC Installed
NNA PIC Installed
SCSI PIC Installed
LVDS DC PIC Installed
PIC Not Present
ServerNet ID
is the internal representation of the ServerNet ID of the ServerNet II Switch.
Fabric Setting
is the external ServerNet fabric served by the cluster switch. Possible values are X
Fabric, Y Fabric, or NONE.
Switch Poll Intrvl
is the interval in which SANMAN polls the cluster switch for status. The polling
interval depends on the version of SANMAN that is running on your system and
the state of the link. If a problem occurs with the link, later versions of SANMAN
poll the switch more often until the link is repaired.
Table 9-3. SANMAN Cluster Switch Polling Intervals
SANMAN Version No Error Link Error
T0502 (G06.09) 180 seconds 180 seconds
T0502AAA (G06.09) 180 seconds 180 seconds
T0502AAE (G06.12) 60 seconds 60 seconds
T0502AAG (G06.14) 180 seconds 60 seconds
T0502AAH (G06.16) 180 seconds 60 seconds