ServerNet Cluster Manual
SCF Commands for the External ServerNet SAN
Manager Subsystem
ServerNet Cluster Manual—520575-002
9-20
STATUS CONNECTION Command Example
Fabric Access
indicates the status of the external X and Y fabric connections. Possible values
are:
•
No Error
•
MSEB Missing
•
Link Dead
•
No Response
•
Processor Fabric Down
•
CRU Type Not MSEB
•
No NNA PIC
•
Wrong Fabric
•
Bad Switch Port Number
•
Bad SCB Loaded
•
Bad Switch PIC Type
•
Bad Switch GUID
•
Node Number Mismatch
•
NNA Verify Fail
•
SP I/O Library Call Error
•
System Power Up
•
No MSEB Config Record
•
Bad MSEB Config Record
•
MSEB Config Fetch Error
•
Internal Sys Fabric Down
•
Both LEDs Set
•
TNET Initialization Error
•
Invalid Fabric Parameter
•
Too Many Switches
Port Status Valid
indicates whether the port status information is valid. Possible values are TRUE
and FALSE.
Port Status
indicates the status of the MSEB or ServerNet II Switch port. Possible values are
Link Alive, Link Dead, Dead, Reset, or Uninstalled.
Link Speed
indicates the speed of the link in megabits per second.
Link Lvl Prtcl Rcv
indicates whether Link Receive is enabled. Possible values are ENABLED or
DISABLED.