ServerNet Cluster Manual

SCF Commands for the External ServerNet SAN
Manager Subsystem
ServerNet Cluster Manual520575-002
9-29
STATUS SWITCH Command Example
Flash ID String
indicates whether the manufacturer code and device code stored in FLASH
memory are the expected values. Possible values are Status OK and Status
Bad.
Flash Boot Lckot 0
indicates whether an error occurred because the FLASH lower boot block section
is locked. Possible values are No Error Detected and Error Detected.
Flash Boot Lckot 1
indicates whether an error occurred because the FLASH upper boot block section
is locked. Possible values are No Error Detected and Error Detected.
Cable Detected
indicates whether the power status cables of the UPS subcomponent are
connected. Possible values are TRUE or FALSE.
UPS Response
indicates the result of the UPS response test. Possible values are PASSED or
FAILED.
UPS On Ok Status
indicates the condition of the uninterruptible power supply (UPS) subcomponent of
the cluster switch. Possible values are NORMAL and ABNORMAL.
Mode of Operation
describes how the ServerNet II Switch is currently receiving power. Possible values
are Battery Operation and Line Operation.
Battery Voltage
is the battery voltage. Possible values are Status OK and LOW.
Battery Management
describes the current operational state of the battery contained within the UPS.
Possible values are:
CHARGING
DISCHARGING
FLOATING
RESTING