ServerNet Cluster Manual
SCF Commands for the External ServerNet SAN
Manager Subsystem
ServerNet Cluster Manual—520575-002
9-30
STATUS SWITCH Command Example
Line Regulation
indicates the status of line regulation. Possible values are:
•
Normal Straight Through
•
Step Down (Buck)
•
Step Up (Boost)
Attention Required
describes a condition on the UPS that requires attention. Possible values are:
•
NONE
•
Ground Failure
•
Battery Failure
•
Overloaded
Immediate Attn Req
describes a condition on the UPS that requires urgent attention. Possible values
are:
•
NONE
•
Backfeed Contact Failure
•
Overload (UPS Shut Down)
•
Inverter Under Voltage
Backup Time
is the remaining backup time of the UPS subcomponent of the cluster switch.
Nominal Input Volt
is the input voltage of the UPS subcomponent of the cluster switch.
Primary Power Rail
indicates the status of the Primary Power Rail. Possible values are ON or OFF.
Scndary Power Rail
indicates the status of the Secondary (Backup) Power Rail. Possible values are
ON or OFF.
Switch Port (xx)
displays nine types of status codes for each of the 12 ports on the ServerNet II
Switch. The ports are numbered in the range 00 through 11. Table 9-4 describes
the status variables and lists possible values.