ServerNet Cluster Manual
SCF Commands for the External ServerNet SAN
Manager Subsystem
ServerNet Cluster Manual—520575-002
9-32
STATUS SWITCH Command Example
Blinking LED Ports
indicates which ports on the ServerNet II Switch have their LEDs blinking.
Possible values are:
•
No Port LEDs Blinking
•
All Port LEDs Blinking
•
A horizontal listing of port numbers that are blinking.
Nghbor Port Number
is the port number on the neighbor cluster switch to which the local cluster switch
is connected.
Fabric Setting
is the external ServerNet fabric of the neighbor cluster switch. Possible values are
X, Y, or NONE.
Globally Unique ID
is the Globally Unique ID (GUID) of the neighbor cluster switch.
Configuration Tag
is the last six digits of the configuration tag specified for the neighbor cluster
switch. For more information, see Configuration Tag, defined earlier in this section.
Config Revision
is the version of the configuration running on the neighbor cluster switch.
Firmware Revision
is the version of the firmware running on the neighbor cluster switch.
DU Disabled, Unknown Reason
UN Uninitialized
UK Unknown
TP Target Port Enabled EN Enabled
DS Disabled
UK Unknown
Table 9-4. Switch Port Status Codes and Possible Values (page 2 of 2)
Status Variables Possible Values
Code Description Code Description