ServerNet Cluster Manual
SCF Error Messages
ServerNet Cluster Manual—520575-003
10-11
SANMAN (SMN) Error Messages
Recovery. Reissue the command and specify just one load file attribute (either
FIRMWARE or CONFIG).
SMN Error 00016
Cause. The POSITION attribute was specified in a command with the FIRMWARE
attribute.
Effect. The command is not executed. SCF waits for the next command.
Recovery. Reissue the command without the POSITION attribute.
SMN Error 00017
Cause. A load file attribute (FIRMWARE or CONFIG) was not specified.
Effect. The command is not executed. SCF waits for the next command.
Recovery. Reissue the command and specify a load file attribute of either FIRMWARE
or CONFIG.
SMN Error 00018
Cause. A configuration load file type attribute (CONFIG) was specified without a
POSITION attribute to identify the topology position of the cluster switch.
Effect. The command is not executed. SCF waits for the next command.
Recovery. Reissue the command and specify a POSITION attribute.
SMN Error 00019
Cause. The TOPOLOGY attribute was specified in a command with the FIRMWARE
attribute.
Effect. The command is not executed. SCF waits for the next command.
Recovery. Reissue the command without the TOPOLOGY attribute.
SMN E00016 The POSITION attribute cannot be used with the
FIRMWARE attribute.
SMN E00017 A load file attribute (FIRMWARE or CONFIG) is
required.
SMN E00018 The CONFIG attribute requires a POSITION
attribute.
SMN E00019 The TOPOLOGY attribute cannot be used with the
FIRMWARE attribute.