ServerNet Cluster Manual
SCF Changes at G06.21
ServerNet Cluster Manual—520575-003
I-2
Using SCF Commands for SANMAN
Using SCF Commands for SANMAN
This section describes the changes made to SCF commands for the SNETMON 
product module. The changes are backward compatible and still support the star 
topologies and the 6770 switch. The 6780 switch is also supported, but the syntax for 
specifying each type of switch is different. Also, the output of the commands differs 
depending on the switch type.
For more details, consult the SCF help text for this product module. To access SCF 
help for SANMAN, at the SCF prompt, type:
> HELP SMN
ALTER SWITCH
The syntax for this command has changed. The FABRIC specifier does not change the 
setting of the 6770 switch, but designates which switch to alter. To configure a 6770 
switch for use on a particular fabric, use the new FABRICSETTING attribute. For 
details, see the SCF help.
STATUS CONN
None of the changes to this command affect clusters with the star topologies, but the 
syntax presented earlier in this manual is incorrect when using this product version or 
later. For the correct syntax, see the SCF help.
STATUS SWITCH
None of the changes to this command affect clusters with the star topologies, however 
the syntax presented earlier in this manual is incorrect when using this product version 
or later. For the correct syntax, see the SCF help.
New SCF Error Messages for SANMAN
Because the syntax is different for 6770 and 6780 switches, many new error messages 
have been added in case you use incorrect syntax for your type of switch. For a 
complete listing of SCF error messages for SANMAN, see the ServerNet Cluster 6780 