ServerNet Cluster Manual

Planning for Installation
ServerNet Cluster Manual520575-003
2-16
Two MSEBs Needed for Each Server
PICs for MSEBs That Will Replace SEBs
If slots 51 and 52 of group 01 contain SEBs, you must replace them with MSEBs. The
MSEBs that you install in these slots must contain a single-mode fiber-optic PIC with
the node-numbering agent (NNA) field-programmable gate array (FPGA) in port 6. Port
6 is used to connect fiber-optic cables from the server to a ServerNet II switch. See
Figure 2-4.
If slots 51 and 52 of group 01 already contain MSEBs, check the PICs installed in the
MSEBs in port 6. If the system is running, you can use the OSM Service Connection or
TSM Service Application to determine if a PIC installed in port 6 is an NNA PIC. Check
the PIC Type attribute for the PIC subcomponent of the MSEB. Section 5, Managing a
ServerNet Cluster, shows a TSM display of the PIC attributes.
If the system is not running, you can remove the MSEB and visually check the PIC
installed on the MSEB common base board. The NNA PIC is roughly twice as long as
all other PICs for the MSEB. See Figure 1-11 on page 1-23.
Figure 2-4. Single-Mode Fiber-Optic PIC Installed in Port 6
Note. When installed in an MSEB and viewed on the MSEB faceplate, the single-mode fiber
PIC, multimode fiber PIC, and single-mode fiber NNA PIC are identical in appearance.
vst004.vsd
MSEB
6
5
4
9
10
Port 6 Containing Single-Mode
Fiber-Optic Plug-In Card (PIC)
With Node-Numbering Agent
(NNA FPGA)